Lauder LINEA 2.9.10 – Suspended Ceiling

Category: Tag:

Finishing*

  • Natural (D-s1,d0)
  • Natural (B-s2,d0)
  • Clear varnish (B-s2,d0)
  • Wax Color (B-s2,d0)
  • Wax Color (D-s1,d0)
  • Wax Color MC (B-s2,d0)

* Choice of finish: cf. building classification table

Rear side: 120 Kg / m3 rigid mineral or stone wool acoustic tiles with black fleece facing (600 x 600 mm format; 20 or 22 mm thick)

Modular Dimensions: 1880 x 600 mm and 1265 x 600 mm

Additional information

Form

Linear

Thickness

117 mm

Wood Section

20 x 90 mm

Black rear wooden counter-slats

34 x 45 mm

Spacing between slats

100 mm

Average void area

83 %

Technical Specification

LL-pla-2-91

* Test report, panel with insertion of mineral or stone wool tiles with black fleece facing

** Moist and/or corrosive environments, cf. grid system manufacturer recommendations

LL-pla-2-92

Edging system:

edge-dc

Acoustic Results

Sound absorption has been measured as defined in standard ISO 354. Data related to sound absorption (αp, αw, absorption class) has been calculated in compliance with standard ISO 11654 (Lauder LINEA + addition of acoustic materials).

Lauder LINEA ceiling 2.9.10 + 20 mm MW or SW on E250 mm plenum

LL-pla-2-9-10-acoustic

Weighted index: αw = 0.90

Absorption class: Class A

According to ASTM C423: NRC = 0.90

LL-pla-2-9-10-graphic

Documentation